您好,欢迎来到化拓教育网。
搜索
您的当前位置:首页煅烧石油焦MSDS

煅烧石油焦MSDS

来源:化拓教育网
Revision date : 2007-03-15

Calcined petroleum coke

1. PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NAME: PRODUCT NUMBER: SUPPLIER:

Calcined petroleum coke

000172 (A0045)

Alcan Inc.

Primary Metal Group 1188, Sherbrooke West Montréal, Québec Canada H3A 3G1

* Please call collect for outside calls of North America.

Emergency phone : 1-800-567-7455 * Phone : 514-848-8000

Fax : 514-848-8115/8116

**See section 16 for producer(s) identification** Black odourless solid.

Raw material for electrode production.

APPEARANCE AND ODOUR: USES:

2. COMPOSITION / INFORMATION ON INGREDIENTS

NAME

Calcined petroleum coke Sulfur

743-05-1 7704-34-9

CAS # LD50 LC50

Unknown Unknown

CONC.

> 95% 0.5 - 4.5%

Unknown Unknown

3. HAZARDS IDENTIFICATION

Not hazardous.

4. FIRST AID MEASURES

INHALATION: SKIN CONTACT: EYE CONTACT:

If overcome by high dust concentrations, remove to a ventilated area.

Wash skin thoroughly with soap and water. Do not scrub, since the abrasion may cause irritation.

Flush eyes thoroughly with water, taking care to rinse under eyelids. If irritation persists, continue flushing for 15 minutes, rinsing from time to time under eyelids. If discomfort

continues, consult a physician. Do not rub, since abrasion and damage to the cornea may occur. Not applicable

INGESTION:

5. FIRE-FIGHTING MEASURES

Combustible.

EXTINGUISHING MEDIA:

HAZARDOUS COMBUSTION PRODUCTS:

Material safety data sheet

Moderate fire hazard if exposed to heat, fire or strong oxidising agents. Extinguishing media: dry chemical, water mist. In case of fire, wear self-contained breathing apparatus and fire-resistant clothing.

If heated to decomposition, emits carbon monoxide, carbon dioxide, sulphur dioxide and nitrogen oxides.

1/4

Revision date : 2007-03-15

Calcined petroleum coke

6. ACCIDENTAL RELEASE MEASURES

Avoid spreading dust. Avoid contaminating surface water, waterways or sewers leading to surface water. Collect and place in clearly-identified appropriate containers. Use methods which do not result in environmental contamination. Recycle if possible.

7. HANDLING AND STORAGE

HANDLING PRECAUTIONS: STORAGE CONDITIONS:

Avoid generating dust during handling. Coke dust is electrically conductive and can cause short circuits. Equipment must be grounded.

Store away from oxidising agents. Ensure that airborne dust is not generated during storage.

8. EXPOSURE CONTROLS / PERSONAL PROTECTION

Provide general and local ventilation to maintain concentrations of air contaminants below recommended standards. Wear eye and respiratory protection (goggles and mask), or a full-face respirator if necessary. Wear gloves.

EXPOSURE LIMITS:

ACGIH (TLV) OSHA (PEL) TWA STEL TWA CEILING

Calcined petroleum coke None None None None

Sulfur None None None None

33

15 mg/m None Nuisance particulates tot. (PNOS ) 10 mg/m None

33

5 mg/m None Respirable dust 3 mg/m None

(ACGIH = American Conference of Governmental Industrial Hygienists; TLV = Threshold Limit Value; OSHA = Occupational Safety and Health Administration

[USA]; PEL = Permissible Exposure Limit; TWA = Time-Weighted Average; STEL = Short Term Exposure Limit; C = Ceiling value)

9. PHYSICAL AND CHEMICAL PROPERTIES

PH:

Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable 2.1 Insoluble. Not determined

BOILING POINT: MELTING POINT: VAPOUR PRESSURE:

VAPOUR DENSITY (AIR = 1): EVAPORATION RATE:

RELATIVE DENSITY (WATER = 1): WATER SOLUBILITY: ODOUR THRESHOLD:

FLASHPOINT:

AUTOIGNITION TEMPERATURE: LOWER FLAMMABLE LIMIT: HIGHER FLAMMABLE LIMIT: EXPLOSIVE PROPERTIES: NFPA FIRE CODE:

OXIDISING PROPERTIES: PARTITION COEFFICIENT (N-OCTANOL/WATER):

Not applicable Not determined Not applicable Not applicable Not determined 1

Not applicable Not determined

10. STABILITY AND REACTIVITY

STABLE (YES/NO): Yes

CONDITIONS AND MATERIAL TO AVOID: HAZARDOUS DECOMPOSITION PRODUCTS:

Material safety data sheet

Incompatibility with strong oxidizers, especially when heated. If heated to decomposition, emits carbon monoxide, carbon dioxide, sulphur dioxide and nitrogen oxides.

2/4

Revision date : 2007-03-15

Calcined petroleum coke

11. TOXICOLOGICAL INFORMATION

ROUTES OF EXPOSURE: INHALATION: Yes EYE CONTACT: No

INGESTION:

SKIN CONTACT:

No No

No

SKIN ABSORPTION:

ACUTE EFFECTS: INHALATION: SKIN CONTACT: EYE CONTACT: INGESTION:

Inhalation of high concentrations of these inert nuisance particulates can result in mild irritation of the respiratory tract.

May cause irritation through mechanical abrasion. May cause irritation through mechanical abrasion. Not applicable

CHRONIC EFFECTS:

Prolonged and repeated overexposure to dust can lead to a benign pneumoconiosis.

MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE TO THE PRODUCT: Not determined CARCINOGENICITY / MUTAGENICITY / REPRODUCTIVE None of the ingredients present at concentrations equal to or

greater than 0.1% are listed as a carcinogen or potential TOXICITY:

carcinogen by IARC, NTP or OSHA.

[IARC = International Agency for Research on Cancer; NTP = National Toxicology Program (USA); OSHA = Occupational Safety and Health Administration (USA)]

12. ECOLOGICAL INFORMATION

No effects are expected from this insoluble product because insolubility leads to non-bioavailability.

13. DISPOSAL CONSIDERATIONS

Recycle if possible. Dispose of waste in accordance with federal, state, or local regulations.

14. TRANSPORT INFORMATION

TDGR: not regulated CFR 49: not regulated IMO: not regulated ICAO: not regulated IATA: not regulated

[TDGR = Transport of Dangerous Good Regs.(Canada). CFR 49 = Code of Federal Regs.(USA). IMO = International Maritime Organization. ICAO = International Civil Aviation Organization. IATA = International Air Transport Association)]

15. REGULATORY INFORMATION

WHMIS CLASSIFICATION (CANADA): EUROPEAN UNION CLASSIFICATION: WARNING SYMBOL: WARNING WORD: RISK PHRASES: SAFETY PHRASES:

Not controlled Not classified None None None None

Material safety data sheet 3/4

Revision date : 2007-03-15

Calcined petroleum coke

USA REGULATIONS :

Section 313 Supplier Notification This product does not contain any chemicals in concentrations subject to the reporting requirements of section 313 of the Emergency Planning and Community Right-To-Know Act of 1986 (Title III of SARA) and of 40 CFR 372.

16. OTHER INFORMATION

Suppliers or plants :

Alcan Inc. Primary Metal Group Arvida Works P.O. Box 1500 Emergency phone : 1-800-567-7455 * Jonquière, Québec Phone : 418-699-2111, poste 2734 Canada G7S 4L2 Fax : 418-699-2043

Alcan Inc. Primary Metal Group

Strathcona Works Emergency phone : 1-800-567-7455 * P.O. Box 5850 station L Phone : 780-467-9422 Edmonton, Alberta, Canada Fax : 780-467-0461 T6C 4G3

* Please call collect for outside calls of North America.

ABBREVIATIONS:

WHMIS = Working hazardous material information system. CAS number = Chemical Abstracts Service Registry Number.

LD50 = Lethal dose 50%; LC50 = Lethal concentration 50%; LCL0 = Lowest published lethal concentration.EU = European Union.

* Although the information in this SDS was obtained from sources which we believe to be reliable, it cannot be guaranteed. In addition, this information may be used in a manner beyond our knowledge or control. The information is therefore provided for advice purposes only, without any representation or warranty express or implied. *

Prepared by Alcan Toxicology Service

Phone: 418-699-2707 P.O. Box 1500, Jonquière (Quebec)

Fax: 418-699-2993 Canada, G7S 4L2

E-mail: servicetoxico@alcan.com

DATE OF THE PREVIOUS REVISION: 2004-09-09

REASON FOR REVISION: Revision after three (3) years, according to WHMIS (Canada).

Material safety data sheet 4/4

因篇幅问题不能全部显示,请点此查看更多更全内容

Copyright © 2019- huatuo9.cn 版权所有 赣ICP备2023008801号-1

违法及侵权请联系:TEL:199 18 7713 E-MAIL:2724546146@qq.com

本站由北京市万商天勤律师事务所王兴未律师提供法律服务